Description
Davies Craig EWP150 alloy pump & LCD controller combo
Muscle up your engine cooling system with the Davies Craig EWP 150 alloy Electric Water Pump and the LCD EWP /Fan Digital Controller.
Like all EWPs, this advanced unit is designed for remote mounting in the engine bay to satisfy those higher horsepower, turbocharged, supercharged and worked engines which develop excessive heat.
EWP COMPONENTS |
HARDWARE BAG COMPONENTS |
||
Description |
Qty |
Description |
Qty |
EWP150 Alloy Short Kit |
1 |
Scotch Lock |
1 |
EWP & FAN Controller |
1 |
Ring Terminal |
1 |
Inline Adaptor |
1 |
Ring Terminal (Yellow) |
1 |
Wiring Harness (10A Fuse) |
1 |
Self Tap Screws |
1 |
Thin Rubber Sleeves |
2 |
Temp Sensor Assembly |
1 |
Hose Clamps |
4 |
||
EWP Hardware Bag |
1 |
Technical Specifications | ||||
Technical Specifications – EWP150 | Technical Specification – LCD Controller | |||
Operating voltage | 3V DC to 15V DC | Voltage range | 12V DC to 29V DC | |
Maximum current | 10A @ 13V | Display LCD size | 70mm (2.76 ) x 60mm (2.36 ) | |
Flow rate (max) | 150L/min (39.63 US gal/min) @ 13V DC | Maximum current | 12Amps | |
Operating temp. | -40 to 130 C (-40 to 266 F) | Warning alarm | High & low Temp., Above set temp., Sensor short circuit, Pump error, High & low voltage and Sensor open circuit | |
Pump design |
Clockwise centrifugal with volute chamber |
Targeted (set) temperatures | Singular degrees from: 60 C (140 F) to 100 C (212 F) |
|
Pump weight | 1,170 grams (2.6 lb) | Memory | Set & targeted temperature | |
Pump material | Aluminium (Powder Coated) | Fan cut-in temp. | 3 C (5.4 F) above the targeted (set) temperature | |
Burst pressure | 500 kPa (72.5 psi) | Controller type | PCB with micro-processor | |
Seal | Ceramic face seal | Sensor type | Thermister in housing | |
Fits hose size |
35mm to 51mm (1.38 to 2 ) |
Overrun/ shutdown | -10 C (14 F) below set/target temperature or 3 minutes | |
Indicators | Temperature, power, EWP, test, fan, high & low temp, voltage, above set temperature (with alarm) | |||
Internal Thread | -Inlet & Outlet: -16AN (12) | Weight | 100 grams (3.5 oz) | |
Push-On fitting Size |
EWP Inlet & Outlet 38mm
|
Dimensions |
Length = 95mm (3.7″) Width = 130mm (5.1″) Depth = 25mm (1 ) |
The compact EWP 150 alloy unit is manufactured with AN-16 internal inlet and outlet threads for neat, tight screw-in fitting applications. This rugged alloy hi-flow electric water pump is designed to complement or replace the engine s existing mechanical water pump. This essential performance part increases power to
your vehicle s drive wheels and improves coolant temperature control.
The EWP 150 is a universal, do-it-yourself, easy installation fitment to engines up to seven litres. By removing the parasitic power losses of belt-driven water pumps, the EWP 150 releases up to 10kW (13hp) of extra power, increased torque and fuel savings. Combine it with the LCD EWP /Fan Digital Controller and the pump continues to run after you ve switched off, eliminating heat soak and extending engine life.
The EWP 150 and LCD EWP /Fan Digital Controller Combo Kit is the most economical way to increase horsepower and save on fuel consumption whilst caring for your engine.
LCD EWP & FAN DIGITAL CONTROLLER – 12 & 24 VOLT
This LCD EWP / Fan Digital Controller (Part #8001) is Australian designed and as part of this Australian manufacturing company s continuous improvement program this advanced Digital Controller boasts a suite of enhancements.
The updated LCD Digital Controller how has two specific functions. This unique Controller will now manage the operation of the EWP by varying the speed of the EWP in response to the temperature of the engine and manage control of your electric engine fan. The Controller has a push-button on the facia panel that offers target temperatures Singular degrees from 60 C (140 F) to 100 C (212 F).
Generally, higher engine temperature will offer improved fuel efficiency and lower engine temperature more power. The LCD Digital Controller will now operate the engine s electric fan automatically once the engine has reached 3c above the target temperature. A significant benefit too is the Controller allows the EWP to run on after ignition shutdown to reduce heat soak. It is recommended that engine operational temperatures be checked with manufacturer.
Features
- – Black & White Numerical Screen
– Celsius or Fahrenheit display option - – Select any set temp range from 60 C (140 F)to 100 C (212 F)
– Set / targeted temperature memory
– Override feature to assist bleeding EWP & fail safe
– Input voltage display
– Compatible with billeted style Electric Water Pumps
Warning Alarms:
- – Plus 10 C (14 F) set/target temperature
– Under temp 40 C after 5 mins
– Temp sensor error
– Over or under voltage
– EWP error
Product Selection Guide |
|||||||
---|---|---|---|---|---|---|---|
Application | Pump Model | Pump Kit | Pump Combo | Controller / Switch | |||
Part # 12 V |
Part # 24 V |
Part# 12 V |
Part # 24 V |
Part # 12 V |
Part # 24 V |
||
Motorbike up to 500cc (Standard) | EBP 15 | 9001 | 0444 or 0455 | ||||
Motorbike 500cc – 1000cc (Std) | EBP 23 | 9050 | 0444 or 0455 | ||||
Motorbike 1000cc – 2000cc (Std) | EBP 25 | 9005 | 0444 or 0455 | ||||
Vehicle Heater System (Standard) | EBP 23 | 9050 | 0444 or 0455 | ||||
LPG (Butane) System (Standard) | EBP 23 | 9050 | 0444 or 0455 | ||||
Intercooler (depending on capacity) |
EBP 23 | 9050 | |||||
EBP 25 | 9005 | ||||||
EBP 40 | 9040 | 9041 | 0444 or 0455 | 0444 or 0455 | |||
EWP 80 | 8005 | 8907 | |||||
Engines up to 2.0L (Standard) | EWP 80 | 8005 | 8907 | 8001 | 8001 | ||
Engines up to 2.0L – 3.5L (Standard) | EWP 115 | 8025 or 8040 |
8026 or 8041 |
8930 or 8950 |
8931 or 8951 |
8001 | 8001 |
Engines up to 3.5L – 5.0L (Standard) | EWP 130 | 8080 | 8081 | 8990 | 8991 | 8001 | 8001 |
Engines 5.0L or greater (Standard) | EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Modified Engines Supercharged/Turbo |
EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Drag Racing, Drifting & Speedway | EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Off Road / 4WDs | EWP 130 | 8080 | 8081 | 8990 | 8991 | 8001 | 8001 |
Solar Hot Water Systems (depending on size) | EBP 15 | 9001 | 0444 or 0455 | ||||
EBP 23 | 9050 | 0444 or 0455 | |||||
EBP 25 | 9005 | 0444 or 0455 | |||||
EBP 40 | 9040 | 9041 | 0444 or 0455 | 0444 or 0455 |