Description
Davies Craig EWP130 alloy pump & LCD controller combo
Turbocharge your engine cooling with the Davies, Craig EWP 130 alloy Electric Water Pump. Like all the EWPs, this unit is designed for universal engine fitment, to satisfy those larger and higher horsepower, turbocharged, supercharged and worked engines which develop excessive heat. Combine it with the LCD EWP /Fan Digital Controller and the pump continues to run after you ve switched off, eliminating heat soak and extending engine life. The EWP 130 and LCD EWP /Fan Digital Controller Combo Kit is the most economical way to increase horsepower and save on fuel consumption whilst caring for your engine.
The EWP 130 configuration mirrors the highly successful EWP 80 which offers a numerous selection of attachment options, including elbow and straight adaptors which can be bolted on to both the inlet and outlet for simple remote engine mounting.
The EWP 130 will be supplied with one each of the 35mm (1 ) straight and elbow alloy adaptors, O rings and mounting hardware along with two 3mm ( ) rubber adaptor sleeves. The respective 38 mm (1 ) alloy adaptors and 6mm ( ) rubber adaptor sleeves are optional.
This rugged alloy hi-flow electric water pump is designed to complement or replace the engine s existing mechanical water pump. This essential performance product increases power to your vehicle s drive wheels and improves coolant temperature
control. By removing the parasitic power losses of belt-driven water pumps, the EWP 130 releases up to 10kW (13hp) of extra power, increased torque and fuel savings.
KIT CONTENTS |
|
DESCRIPTION |
UNITS |
EWP130 Alloy 12 Volt Pump |
1 |
EWP/FAN LCD Controller | 1 |
Alloy elbow adaptor – 35mm (1 ) | 1 |
Alloy straight adaptor – 35mm (1 ) | 1 |
Hose Clamps | 4 |
Rubber adaptor sleeve – 3mm ( ) | 4 |
EWP Adaptor O-Ring | 2 |
Wiring Harness Digital Controller | 1 |
Inline Adaptor 5/16″ | 1 |
EWP130 Combo Hardware Bag | 1 |
Instructions | 1 |
Technical Specifications EWP130 |
|
Voltage | 12 Volt Pump |
Operating voltage | 3V DC to 15V DC |
Maximum current | 10A @ 13V |
Flow rate (max) |
130 L/min (34.34 US gal/min) @ 13V DC |
Operating temp. | -40 to 130 C (-40 to 266 F) |
Pump design | Clockwise centrifugal with volute chamber |
Pump weight |
1,226grams (2.7 lb) |
Pump material |
Aluminium (Powder Coated) |
Burst pressure |
500 kPa (72.5 psi) |
Seal | Ceramic face seal |
Fits hose sizes |
35mm to 51mm (1 to 2 ) |
LCD EWP / FAN CONTROLLER
For optimum control of Davies, Craig 12 Volt and 24 Volt Electric Water Pumps.
Suits EWP 80, EWP 115, EWP 130, EWP 150 and Thermatic Fans.
The LCD EWP /Fan Digital Controller has two specific functions. This unique Digital Controller will manage the operation of the EWP by varying the speed of the pump in response to the coolant temperature and manage control of your electric engine fan. The Controller has a push-button to lock in any one of the nine targeted/set temperatures. It s highly recommended you set/target the Controller to closely match your engine s existing thermostat temperature.
Generally, higher engine temperature will offer improved fuel efficiency and lower engine temperature more power. The Digital Controller will operate the engine s electric fan automatically once the engine has reached 3 C (5.4 F) above the targeted (set) temperature. Another significant benefit is that the Controller allows the EWP to run on after ignition shutdown to eliminate heat soak.
Technical Specifications LCD Controller |
|
Voltage Range | 12 Volt DC to 29V DC |
Display LCD Size | 70mm (2.76 ) x 60mm (2.36 ) |
Maximum current | 12A |
Warning Alarm |
High & low Temp., Above set temp., Sensor short circuit, Pump error, High & low voltage and Sensor open circuit |
Targeted Set Temp Range | Singular degrees from: 60 C (140 F) to 100 C (212 F) |
Memory | Set & targeted temperature |
Fan Cut-in Temp | 3 C (5.4 F) above the targeted (set) temperature |
Controller Type |
PCB with micro-processor |
Sensor Type |
Thermister in housing |
Overrun / Shutdown |
10 C (14 F) below set/target temperature or 3 |
Indicators | Temperature, power, EWP, test, fan, high & low temp, voltage, above set temperature (with alarm) |
Weight |
100 grams (3.5 oz) |
Dimensions |
Length = 95mm (3.7″) Width = 130mm (5.1″) Depth = 25mm (1 ) |
Features
- – Black & White Numerical Screen
– Celsius or Fahrenheit display option - – Select any set temp range from 60 C (140 F)to 100 C (212 F)
– Set / targeted temperature memory
– Override feature to assist bleeding EWP & fail safe
– Input voltage display
– Compatible with billeted style Electric Water Pumps
Warning Alarms:
- – Plus 10 C (14 F) set/target temperature
– Under temp 40 C after 5 mins
– Temp sensor error
– Over or under voltage
– EWP error
Product Selection Guide |
|||||||
---|---|---|---|---|---|---|---|
Application | Pump Model | Pump Kit | Pump Combo | Controller / Switch | |||
Part # 12 V |
Part # 24 V |
Part# 12 V |
Part # 24 V |
Part # 12 V |
Part # 24 V |
||
Motorbike up to 500cc (Standard) | EBP 15 | 9001 | 0444 or 0455 | ||||
Motorbike 500cc – 1000cc (Std) | EBP 23 | 9050 | 0444 or 0455 | ||||
Motorbike 1000cc – 2000cc (Std) | EBP 25 | 9005 | 0444 or 0455 | ||||
Vehicle Heater System (Standard) | EBP 23 | 9050 | 0444 or 0455 | ||||
LPG (Butane) System (Standard) | EBP 23 | 9050 | 0444 or 0455 | ||||
Intercooler (depending on capacity) |
EBP 23 | 9050 | |||||
EBP 25 | 9005 | ||||||
EBP 40 | 9040 | 9041 | 0444 or 0455 | 0444 or 0455 | |||
EWP 80 | 8005 | 8907 | |||||
Engines up to 2.0L (Standard) | EWP 80 | 8005 | 8907 | 8001 | 8001 | ||
Engines up to 2.0L – 3.5L (Standard) | EWP 115 | 8025 or 8040 |
8026 or 8041 |
8930 or 8950 |
8931 or 8951 |
8001 | 8001 |
Engines up to 3.5L – 5.0L (Standard) | EWP 130 | 8080 | 8081 | 8990 | 8991 | 8001 | 8001 |
Engines 5.0L or greater (Standard) | EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Modified Engines Supercharged/Turbo |
EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Drag Racing, Drifting & Speedway | EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Off Road / 4WDs | EWP 130 | 8080 | 8081 | 8990 | 8991 | 8001 | 8001 |
Solar Hot Water Systems (depending on size) | EBP 15 | 9001 | 0444 or 0455 | ||||
EBP 23 | 9050 | 0444 or 0455 | |||||
EBP 25 | 9005 | 0444 or 0455 | |||||
EBP 40 | 9040 | 9041 | 0444 or 0455 | 0444 or 0455 |