Description
Davies Craig EWP115 alloy pump & LCD controller combo
Take total control of your engine cooling with the Davies Craig EWP 115 Alloy Electric Water Pump and LCD EWP /Fan Digital Controller. The Controller will also manage the operation of your Thermatic Fan.
The EWP 115 (115 litres per minute) pump is suitable for small, medium, large, high-performance and 4WD vehicles. It s a performance accessory that improves engine cooling control and capacity whilst giving you more power and torque and improved fuel economy.
Kit Contents | |||
EWP COMPONENTS |
HARDWARE BAG COMPONENTS |
||
Description |
Qty |
Description |
Qty |
EWP115 Alloy |
1 |
Scotch Lock |
1 |
EWP & FAN LCD Controller |
1 |
Ring Terminal |
1 |
Inline Adaptor |
1 |
Ring Terminal (Yellow) |
1 |
Wiring Harness (10A Fuse) |
1 |
Self Tap Screws |
1 |
Thin Rubber Sleeves |
4 |
Temp Sensor Assembly |
1 |
Hose Clamps |
4 |
Mount Pad Hook & Loop | 1 |
EWP Hardware Bag |
1 |
Technical Specifications | ||||
Technical Specifications – EWP115 | Technical Specification – LCD Controller | |||
Operating voltage | 3V DC to 15V DC | Voltage range | 12V DC to 29V DC | |
Maximum current | 10A @ 13V | Display LCD size | 70mm (2.76 ) x 60mm (2.36 ) | |
Flow rate (max) | 115 L/min (30.38 US gal/min) @ 13V DC | Maximum current | 12Amps | |
Operating temp. | -40 to 130 C (-40 to 266 F) | Warning alarm | High & low Temp., Above set temp., Sensor short circuit, Pump error, High & low voltage and Sensor open circuit | |
Pump design |
Clockwise centrifugal with volute chamber |
Targeted (set) temperatures | Singular degrees from: 60 C (140 F) to 100 C (212 F) |
|
Pump weight | 920 grams (2.3 lb) | Memory | Set & targeted temperature | |
Pump material | Aluminium (Powder Coated) | Fan cut-in temp. | 3 C (5.4 F) above the targeted (set) temperature | |
Burst pressure | 500 kPa (72.5 psi) | Controller type | PCB with micro-processor | |
Seal | Ceramic face seal | Sensor type | Thermister in housing | |
Fits hose sizes & Internal Thread |
35mm to 51mm (1.38 to 2 )
-Inlet & Outlet: -16AN (12) |
Overrun/ shutdown | -10 C (14 F) below set/target temperature or 3 minutes | |
Indicators | Temperature, power, EWP, test, fan, high & low temp, voltage, above set temperature (with alarm) | |||
Push-On fitting Size |
EWP Inlet & Outlet 38mm
|
Weight | 100 grams (3.5 oz) | |
Dimensions |
Length = 95mm (3.7″) Width = 130mm (5.1″) Depth = 25mm (1 ) |
Mechanical belt-driven water pumps run directly off the motor and sap engine power the EWP 115 is hardwired into your electrical system, by-passing the engine and releasing up to an additional 10kw (13hp). Combined with the LCD EWP / Fan Digital Controller, the pump continues to run after you ve switched off, eliminating heat soak and extending engine life.
Davies, Craig s revolutionary, Australian-designed EWP pumps are made from anti-corrosive, lightweight Alloy reinforced with fibreglass. Universal fit allows for easy mounting into the bottom radiator hose. Our kits come with easy-to-understand DIY instructions and everything you need for easy installation, including different adaptors to fit various hose sizes and all necessary electrical wiring.
The EWP 115 and LCD EWP / Fan Digital Controller Combo Pack is the most economical way to increase horsepower and save on fuel consumption whilst caring for your engine.
The Davies, Craig EWP header adaptor kit can replace the mechanical water pump completely. (See EWP Header Adaptors on website)
The world s most advanced total engine cooling management
- universal fit
- more power
- more cooling
- increase fuel efficiency
- extend engine life
- world-leading technology
- lightweight Alloy
LCD EWP & FAN DIGITAL CONTROLLER – 12 & 24 VOLT
This LCD EWP / Fan Digital Controller (Part #8001) is Australian designed and as part of this Australian manufacturing company s continuous improvement program this advanced Digital Controller boasts a suite of enhancements.
The updated LCD Digital Controller how has two specific functions. This unique Controller will now manage the operation of the EWP by varying the speed of the EWP in response to the temperature of the engine and manage control of your electric engine fan. The Controller has a push-button on the facia panel that offers target temperatures Singular degrees from 60 C (140 F) to 100 C (212 F).
Generally, higher engine temperature will offer improved fuel efficiency and lower engine temperature more power. The LCD Digital Controller will now operate the engine s electric fan automatically once the engine has reached 3c above the target temperature. A significant benefit too is the Controller allows the EWP to run on after ignition shutdown to reduce heat soak. It is recommended that engine operational temperatures be checked with manufacturer.
Features
- – Black & White Numerical Screen
– Celsius or Fahrenheit display option - – Select any set temp range from 60 C (140 F)to 100 C (212 F)
– Set / targeted temperature memory
– Override feature to assist bleeding EWP & fail safe
– Input voltage display
– Compatible with billeted style Electric Water Pumps
Warning Alarms:
- – Plus 10 C (14 F) set/target temperature
– Under temp 40 C after 5 mins
– Temp sensor error
– Over or under voltage
– EWP error
Product Selection Guide |
|||||||
---|---|---|---|---|---|---|---|
Application | Pump Model | Pump Kit | Pump Combo | Controller / Switch | |||
Part # 12 V |
Part # 24 V |
Part# 12 V |
Part # 24 V |
Part # 12 V |
Part # 24 V |
||
Motorbike up to 500cc (Standard) | EBP 15 | 9001 | 0444 or 0455 | ||||
Motorbike 500cc – 1000cc (Std) | EBP 23 | 9050 | 0444 or 0455 | ||||
Motorbike 1000cc – 2000cc (Std) | EBP 25 | 9005 | 0444 or 0455 | ||||
Vehicle Heater System (Standard) | EBP 23 | 9050 | 0444 or 0455 | ||||
LPG (Butane) System (Standard) | EBP 23 | 9050 | 0444 or 0455 | ||||
Intercooler (depending on capacity) |
EBP 23 | 9050 | |||||
EBP 25 | 9005 | ||||||
EBP 40 | 9040 | 9041 | 0444 or 0455 | 0444 or 0455 | |||
EWP 80 | 8005 | 8907 | |||||
Engines up to 2.0L (Standard) | EWP 80 | 8005 | 8907 | 8001 | 8001 | ||
Engines up to 2.0L – 3.5L (Standard) | EWP 115 | 8025 or 8040 |
8026 or 8041 |
8930 or 8950 |
8931 or 8951 |
8001 | 8001 |
Engines up to 3.5L – 5.0L (Standard) | EWP 130 | 8080 | 8081 | 8990 | 8991 | 8001 | 8001 |
Engines 5.0L or greater (Standard) | EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Modified Engines Supercharged/Turbo |
EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Drag Racing, Drifting & Speedway | EWP 150 | 8060 | 8061 | 8970 | 8971 | 8001 | 8001 |
Off Road / 4WDs | EWP 130 | 8080 | 8081 | 8990 | 8991 | 8001 | 8001 |
Solar Hot Water Systems (depending on size) | EBP 15 | 9001 | 0444 or 0455 | ||||
EBP 23 | 9050 | 0444 or 0455 | |||||
EBP 25 | 9005 | 0444 or 0455 | |||||
EBP 40 | 9040 | 9041 | 0444 or 0455 | 0444 or 0455 |